Advanced Intelligent Fire Alarm Systems

​

- Microprocessor controlled with increased detection efficiency and functions
- Advanced Protocol, 159 detectors and 159 modules can be connected
- Communication works even against electro magnetic disturbance
- Auto pollution compensation
- All detectors and modules are user friendly and contain rotary switch and addressable features
- 5-32 VDC (24 VDC normal) extensive working voltage range
- Low working current
- Low Profile-Design
- Work towards broader range of improved airflow in a test chamber
- Filter Protection fr Dust and Insects
- Remote Idicator Option available
- Built in Magnetic Test Switch and external tester with remote control
- Two LED's at 360 degrees for easier detection of fire and smoke

​

​

​

​

FCO731 - Optical Smoke Detector

- New mechanical platform with revolutionary chamber offering improved false alarm immunity
• Improved detection across multiple fire types
• Improved resilience to false alarms through dust
• Removed risk of false alarms through insects
- Includes Advanced Protocol
- Available with or without single pole short circuit isolation with status control through Advanced Protocol
- Tri colour LED offering red, green and amber colours
- Rotary decade address switches
- Pure white colour to compliment modern buildings
- 100% mechanical and electrical backwards compatibility

 

- New Base design to compliment the detector

FCOT721 - Combine Detector

- Two sensor multi-criteria fire detector incorporating photoelectric, and thermal sensing elements
- New mechanical platform with revolutionary chamber
- Includes Advanced Protocol
- Available with or without single pole short circuit isolation with status control through Advanced Protocol
- Tri colour LED offering red, green and amber colours
- Rotary decade address switches
- Pure white colour to compliment modern buildings
- 100% mechanical and electrical backwards compatibility
- New Base design to compliment the detector

FCHF741 - ROR Temperature Detector

- Rate of rise heat detectorsity to customise the heat thresholds of each detector to the specific risks found in the application
- Available with or without single pole short circuit isolation with status control through Advanced Protocol
- Tri colour LED offering red, green and amber colours
- Rotary decade address switches
- Pure white colour to compliment modern buildings
- 100% mechanical and electrical backwards compatibility
- New Base design to compliment the detector

FCHR751 - Fixed Temperature Detector

- 58 C° fixed temperature detectorsity to customise the heat thresholds of each detector to the specific risks found in the application
- Available with or without single pole short circuit isolation with status control through Advanced Protocol
- Tri colour LED offering red, green and amber colours
- Rotary decade address switches
- Pure white colour to compliment modern buildings
- 100% mechanical and electrical backwards compatibility
- New Base design to compliment the detector

FCHH761 - High Temperature Detector

- 78 C° fixed temperature detectorsity to customise the heat thresholds of each detector to the specific risks found in the application
- Available with or without single pole short circuit isolation with status control through Advanced Protocol
- Tri colour LED offering red, green and amber colours
- Rotary decade address switches
- Pure white colour to compliment modern buildings
- 100% mechanical and electrical backwards compatibility
- New Base design to compliment the detector

  • Special Detectors 

  • Detectors

2251CTLE - COPTIR™ Detector

- The World's only 4 sensor multi criteria fire detector continually monitoring all four sensor elements in making the fire/no fire decision
- Uses sophisticated and responsive algorithms
- Ultra-immune to nuisance sources yet sensitive to the widest range of fire types
- Best immunity to false alarms

7251 - Lazer™ Detector

- The most sensitive point detector in the world
- Uses a laser instead of LED's to sense smoke
- Superior early warning performance
- Nine sensitivity levels

DNRE - Duct Detector

- Senses airflow speeds ranging from 0.5-20 meters per second - Flexible to fit square and rectangle configurations - Conventional and intelligent versions 

FTX-P1 - FILTREX™ Detector

- High density filter removes particulate down to 34 microns
- Air delivery system is separately powered and fully supervised
- Filter is easily field replaceable
- Approved for use in high airflow (20m/s)
- Optional remote LED
- Rotary decade address switches
- No modification required to panels compatible with Series 200 plus intelligent photoelectric sensor
- Twin alarm LEDs provide 360° visibility

2251EIS - Ex-Proof Optical Smoke Detector

- Compatible with existing System Sensor Protocol
- Low profile design
- Reliable analogue addressable communications
- Rotary decade address switches
- Tamper Resistant
- Twin LED indicators provide 360° visibility
- Built in test switch
- Must be used in conjunction with IST200 Translator Module and Y72221 Galvanic Isolator
- Compatible with the existing standard intelligent sensor base

6500 - Beam Detector

- Up to 1000m range
- Pulsed wide IR beam-stable and low power
- Easy alignment process-sight and display
- Drift/alignment compensation
- Advanced protocol vesion

  • Modules

M201E - Output Module

Single output module

​

M210E - Single Input Module

Single input module

​

M220E - Dual Input Module

Dual input module in the same module case

​

M221E - Dual Input Single Output Module

İki giriÅŸ ve tekli çıkış modülünü tek kasada barındıran modüldür.

​

M210-CZR Conventional Zone Module

Up to 20 conventional detector, conventional supervise zone module

M501 - Mini Input Module

Single input module

IM10 - Ten Input Module

Ten input module, in the same module case

​

CR6 - Six Relay Output Module

Six output module, in the same module case

​

SC6/CZ6 - Six Supervised Output Module / Six Conventional Zone Interface Module

Six supervised output module, in the same module case / Six conventional zone module, in the same module case

  • Call Points

MCP5A Call Point

- Unique ‘Plug & Play' installation concept
- Total ‘Flex-Ability' in the choice of operating element
- Anti-Tamper facility
- Enhanced aesthetics
- Fully approved to the latest standards
- Backward compatibility 

 

​

​

WCP5A Call Point

- Sealed to IP67
- Unique 'Plug & Play' installation concept
- Total 'Flex-Ability' in the choice of operating element
- Anti-Tamper facility
- Enhanced aesthetics and compact design
- Fully approved to the latest standards
- CPD Approved

WCP5IS Call Point

- Sealed to IP67
- Unique 'Plug & Play' installation concept
- Total 'Flex-Ability' in the choice of operating element
- Anti-Tamper facility
- Enhanced aesthetics and compact design
- Fully approved to the latest standards
- CPD Approved

  • Sounder/Strobe 

BSO - Base Sounder

- Large cable access
- Rear or surface cable entry
- Loop continuity spring
- High quality robust materials for longer life
- UV stable materials
- Robust construction for added impact resistance 

BST - Base Strobe

- Large cable access
- Rear or surface cable entry
- Loop continuity spring
- High quality robust materials for longer life
- UV stable materials
- Robust construction for added impact resistance

BSS - Base Sounder Strobe

- Large cable access
- Rear or surface cable entry
- Loop continuity spring
- High quality robust materials for longer life
- UV stable materials
- Robust construction for added impact resistance

  • Panels

WSO - Wall Sounder

- Large cable access
- Rear or surface cable entry
- Loop continuity spring
- High quality robust materials for longer life
- UV stable materials
- Robust construction for added impact resistance

WST - Wall Strobe

- Large cable access
- Rear or surface cable entry
- Loop continuity spring
- High quality robust materials for longer life
- UV stable materials
- Robust construction for added impact resistance

WSS - Wall Sounder Strobe

- Large cable access
- Rear or surface cable entry
- Loop continuity spring
- High quality robust materials for longer life
- UV stable materials
- Robust construction for added impact resistance

FCE2000 - Advanced Intelligent Fire Alarm Panel

- Intelligent and advanced intelligent protocols
- Up to 10 km. loop lenght (max. 1µ, max. 2 km.)
- It has range from 1 up to 1000 loops
- Modular concept
- 1000 events history
- Wide LCD display (4X40 characters)
- Up to 40 characters user point message
- Fully conrolled with alpha-numeric keypad
- Unlimited network capability by FCENet
- Directlt connection to any 3rd party via inbuilt MODBUS port or TCP/IP gateway
- Enhanced module fonction combinations
- Easy to install, network, configure and maintain
- Class A or Class B loop line option can be selected from software
- Shortcut keys for easy and fast transaction processing capability with programable software, user friendly solutions
- Easy and fully functional panel keypad
- Graphic display, remote control and upload/download software
- Prossibility to change the day and night detection level
- Four level of detection set possibility
- Sequential automatic system control (walktest)
- Three level password protection
- Optional thermal printer
- Independent group and zone identification and programmability


FCE2000R - Repeater

- Intelligent multi-protocol fire alarm control panel 
- Connects to MODBUS peripheral bus 
- 4,7" Touch Screen (8 Shades of Blue) 
- 1000 events history 
- All operating and monitoring functions realized using touch panel 
- Controls for system reset, accept, mute, silence alarms and self test 
- Directly connection to any 3rd party network with USB2.0, RS485 
- Easy to install, network, maintain

FCEGRAPH - Graphical Monitoring Software

- Schematic layout
- Intuitive control screen layout
- Fire System Management tools
- Fire locations shown on multi level map
- Print location map
- Multiple users with individual passwords
- Simple and user friendly
- Full design/layout control

bottom of page